| 2-stage chemical
absorber plant for abatement of ehtylen oxid in an acid solution, with vertical
pump , heat exchanger , reactors, instruments and control cabinet , erection
and start-up in March 1999, efficiency > 99.9 % , all materials corrosion
proof (PE,PP, Hastelloy, ECTFE coated) |
|
We give advice for:
- process
design
- research of basic
data
- calculation of
relevant parameters
- conceptual
studies
- project
management
- basic and detail
engineering
- complete order
handling
- compliance of time
schedule budget
- Software
- modelling for
process design
- databases for
chemical and physical properties
- adopting of
existing software to actual needs
|
|